EcoMax 3S: A Split Cooling and Heating Choice for Changing Seasons
Explore VETHY EcoMax 3S as a GMCC twin-rotary split choice for seasonal cooling and heating, with clear ratings, practical placement and a defined vehicle offer.
Read the guide ↗
VETHY EcoMax 3S 12V split truck air conditioner with 2,200 W cooling, 2,000 W heating and GMCC twin-rotary compressor. Specifications and US fleet RFQ.
| Parameter | 12V DC |
| Cooling capacity | 2200 W |
| Cooling electrical input | 588 W |
| Cooling current | 20–49 A |
| Heating capacity | 2000 W |
| Heating electrical input | 624 W |
| Heating current | 22–52 A |
| Refrigerant charge | 500 g |
| Complete set net weight | 25 kg |
| Complete set gross weight | 29 kg |
| Refrigerant | R134a |
| Compressor type | Twin-rotary |
| Compressor brand | GMCC |
| Compressor displacement | 13 cc |
Compare the 12V and 24V table and original specification graphic below. Confirm application and installation details for the exact configuration.


| Heating capacity | 2,000 W (12V) / 2,200 W (24V) |
| Refrigerant charge | 500 g (12V) / 610 g (24V) |
| Compressor power | 645 W |
| Refrigeration oil / Volume | VG-74 / 250 ml |
| Evaporator airflow | 400 m³/h |
| Condenser airflow | 1500 m³/h |
| Evaporator fan motor | Brushless motor |
| Condenser fan motor | Brushless motor |
| Indoor net / gross weight | 6.9 / 10.5 kg |
| Outdoor unit dimensions | 799 × 180 × 430 mm |
| Indoor unit dimensions | 638 × 335 × 187 mm |
12V HEATING & COOLING SPLIT SYSTEM
Specify both comfort modes in your sleeper-cab project. EcoMax 3S combines a GMCC twin-rotary compressor with separate indoor and outdoor units, giving US fleet buyers a 12V option to evaluate for cooling and heating.
For fleets, distributors, upfitters and OEM purchasing teams.
For fleets, distributors and vehicle integrators evaluating a combined cooling and heating package, EcoMax 3S gives each operating mode a separate capacity, input-power and current rating. Use those figures to develop your vehicle-specific electrical and acceptance plan.
Published 12V cooling and heating ratings help your team define requirements for both operating modes.
A specified compressor brand and technology for your technical review and purchasing documentation.
Both evaporator and condenser fans use brushless motors, with airflow ratings listed separately below.
Compare the 12V and 24V configurations below. The complete product graphic is available in the next section.
| Parameter | 12V DC | 24V DC |
| Cooling capacity | 2200 W | 2600 W |
| Cooling electrical input | 588 W | 792 W |
| Cooling current | 20–49 A | 10–33 A |
| Heating capacity | 2000 W | 2200 W |
| Heating electrical input | 624 W | 840 W |
| Heating current | 22–52 A | 12–35 A |
| Refrigerant charge | 500 g | 610 g |
| Complete set net weight | 25 kg | 23 kg |
| Complete set gross weight | 29 kg | 27 kg |
| Refrigerant | R134a | |
| Compressor type | Twin-rotary | |
| Compressor brand | GMCC | |
| Compressor displacement | 13 cc | |
| Compressor power | 645 W | |
| Refrigeration oil / Volume | VG-74 / 250 ml | |
| Evaporator airflow | 400 m³/h / Brushless motor | |
| Condenser airflow | 1500 m³/h / Brushless motor | |
| Evaporator fan motor | Brushless motor | |
| Condenser fan motor | Brushless motor | |
| Indoor unit dimensions | 638 × 335 × 187 mm | |
| Outdoor unit dimensions | 799 × 180 × 430 mm | |
| Indoor package dimensions | 695 × 485 × 295 mm | |
| Outdoor package dimensions | 940 × 330 × 530 mm | |
| Indoor net / gross weight | 6.9 / 10.5 kg |
12V and 24V are separate configurations. Select the required voltage when ordering.
Dimensions retain the order shown in the specification graphic. Confirm mounting details for the individual vehicle.
Complete set weights include the indoor unit. Compressor power is a component rating, distinct from complete-system electrical input.
A semi-truck installation starts with the actual tractor and duty cycle. Align your installer, maintenance team and purchasing team on these details before ordering a production batch.
Build a common specification before scaling across vehicles, branches or dealer locations.
Confirm the 12V model, included parts, installation scope, operating conditions and delivery destination.
Agree on sample quantities and acceptance criteria, then capture installation, comfort and energy results.
Request a confirmed parts list, packaging, labeling, warranty terms, service parts and applicable documentation.
Use the approved sample to agree on production quantity, lead time, shipment terms and service support.
Cooling capacity is 2,200 W, with rated electrical power of 588 W and rated current of 20–49 A. Heating capacity is 2,000 W, with rated electrical power of 624 W and rated current of 22–52 A. Capacity is thermal output; electrical power is the input load.
Fit must be reviewed for the specific tractor model, year and sleeper layout. Provide indoor and outdoor mounting dimensions, cab photos, service clearances and the proposed 12V power source. The split layout does not establish universal vehicle compatibility.
The 2,000 W heating rating alone does not establish low-temperature performance. Provide your minimum ambient temperature and comfort target, and request operating limits and validation for the proposed configuration before specifying it as the sole heating source.
Plan for both operating modes and the other parked-cab loads. Cooling and heating use different input-power and current ratings. Confirm the auxiliary battery, recharge schedule, protected wiring and low-voltage protection settings with the installer, then measure real energy use in a pilot.
Send pilot and annual quantities, destination ZIP code, vehicle details, intended operating temperatures, required included parts, service-spares needs and documentation requirements. Ask for a configuration-specific quotation and a written sample-to-production plan.
Review VX3000SP: 7,000 BTU/h cooling, 20–45 A rated current and automatic oscillation in the 12V configuration.
US FLEET · DISTRIBUTOR · OEM INQUIRY
Request an EcoMax 3S 12V quotation for your pilot, fleet rollout or distribution program.
Email opens an editable request in your mail app. Or contact info@vethy.com and include the details below.
Request configuration-specific installation documentation and commercial terms with your quotation.
No. Select the voltage-specific configuration. Cooling output, electrical input and current must be read from that column of the specification table.
Send the vehicle model and year, mounting measurements, electrical supply, usable battery energy and duty cycle. The specification sheet does not guarantee fitment or overnight runtime; validate the complete installation in a pilot.
Request the included-parts list, installation documentation, applicable test reports, warranty scope and commercial terms for the exact quotation. Accessories and terms must be confirmed before ordering.
Ratings checked against the original specification graphic. Reviewed October 25, 2026.
Explore power planning, cabin comfort, installation and ownership with guides written around this model.
Explore VETHY EcoMax 3S as a GMCC twin-rotary split choice for seasonal cooling and heating, with clear ratings, practical placement and a defined vehicle offer.
Read the guide ↗Understand VETHY EcoMax 3S GMCC twin-rotary references, separating compressor identity and component fields from whole-unit ratings and the actual vehicle project.
Read the guide ↗Use VETHY EcoMax 3S heating references in a defined seasonal vehicle brief, with separate output and electrical data, practical placement and realistic scope.
Read the guide ↗Plan VETHY EcoMax 3S energy use with cooling and heating data kept separate, clear session scope and realistic vehicle supply and charging information.
Read the guide ↗Explore VETHY EcoMax 3S split placement for a roof-conscious vehicle design, coordinating cabin use, outdoor surroundings, routing and a clear installation scope.
Read the guide ↗Keep EcoMax 3S airflow care connected to the actual split installation, normal cabin arrangement and separate cooling and heating observations across seasons.
Read the guide ↗